medin‑NC3

Product advantages
Independent of an external air supply thanks to the high-performance turbine
All major NIV modes
HFNC and nCPAP modes combined in a single device
Leak compensation in all CPAP modes
MediTRIG: Integrated trigger and apnea monitoring without additional sensors

Categories: , , Tags: , , Product ID: 30734

Description

Solution complète pour la ventilation non invasive

The medin-NC3 is the first turbine-driven CPAP system for non-invasive ventilation of premature infants and newborns. The high-performance turbine allows the device to operate independently of a fixed compressed air supply.

Proven MediTRIG technology is used for the ApneaCPAP mode. The powerful leak compensation function ensures stable and effective therapy.

The device provides all major modes for modern non-invasive ventilation.

For your patients

nCPAP modes. For toddlers.

nCPAP modes are designed so that only the desired CPAP pressure is set. The flow rate is then adjusted according to the patient's condition and any leaks. This prevents unintentional peak pressures, ensures highly effective leak compensation, and reduces oxygen consumption. Flow rate adjustment is very rapid thanks to the high sensitivity of the pressure measurement.

CPAP Apnea Mode

Apnea is detected by the MediTRIG. Cycles are then automatically triggered to stimulate breathing. The frequency, pressure level, and duration of a cycle can be individually adjusted.

NIPPV/BiLevel

Respiratory cycles with fixed settings (pressure level, duration, rate) are administered in addition to PEEP. These respiratory cycles have a higher pressure level and are not delivered synchronously.

High-flow nasal oxygen therapy

nHFT refers to the administration of heated and humidified respiratory gas via a nasal cannula. The gas flow rate delivered is therefore higher than the patient's inspiratory respiratory flow rate. In neonatology, a flow rate greater than 1 L/min is considered high-flow therapy, while for adults, correspondingly higher values ​​should be used.

MediTRIG

The MediTRIG respiratory trigger was specially developed by medin for premature infants and newborns. By combining pressure measurement in the Medijet® generator and signal processing in medin's nCPAP devices, the MediTRIG operates without additional sensors.The MediTRIG detects both central and obstructive apnea.

High-performance turbine

The high-performance turbine allows the medin-NC3 to be independent of a fixed compressed air supply.